Monday, February 06, 2006

Biophysical Needs- Systems

HVAC System

Capable of maintaining a minimum indoor temperature of 68°F building temperature as listed in the International Building Code (2000)

Illumination

Artificial light shall be provided that is adequate to provide an average illumination of 10 foot-candles (107 lux) over the area of the room at a height of 30 inches (762 mm) above the floor level.

Plumbing

Allows for public restrooms in accordance with the occupancy type listed in the Life Safety Code 2003 & State Sanitary Code 2000

Consolidates plumbing in blocked areas to conserve on construction costs

Power

Maintains an efficient use of power while providing sufficient lighting in accordance with the Commercial Building Energy Conservation Code

Emergency Generator to provide lighting in case of a power outage

The means of egress shall be illuminated in accordance with Section 1003.2.11 of the International building Code

Incinerator for boxes and paper products

Used to consolidate waste

Walk-in refrigerated rooms for the storage of goods to be sold

Rooms or spaces having a floor area of 1,000 square feet (93 m2) or more, containing a refrigerant evaporator and maintained at a temperature below 68°F (20°C), shall have access to not less than two exits or exit access doors.

Travel distance shall be determined as specified in Section 1004.2.4 International Building Code 2000, but all portions of a refrigerated room or space shall be within 150 feet (45 720 mm) of an exit or exit access door where such rooms are not protected by an approved automatic sprinkler system. Egress is allowed through adjoining refrigerated rooms or spaces.

0 Comments:

Post a Comment

<< Home